| 10 Series: | 11 Series: | 15 Series: | 18 Series: | 30 Series: | 16 Series: | 17 Series: | 111 Series: | 801 Series: |
![]() |
LOOP SENSOR RELAY![]() |
| 1001 SERIES | Sensitive Current Sensor |
| The Electrodyne type 1001 series relay is used to sense small signal currents used in communication networks and indicate change in state conditions. The relays incorporate two balanced windings, 25 ohms each, which are inserted in each side of the line maintaining longitudinal balance. The must operate current is 19 ma. Isolation between coil and contact is 1000 VRMS. With terminals spaced on a .100 inch grid spacing, it is designed to be mounted into standard sockets or circuit boards on the same lead spacing. We invite your inquiries on the standard relays or any other variations to fit your specific needs. |
FEATURES
APPLICATIONS
|
| SPECIFICATIONS |
| MECHANICAL | ELECTRICAL | |
| Weight: | 4.5 grams max. | Duty Cycle: Continuous |
| Enclosure: | Plastic 94 V0/94-5V | Insulation Resistance: |
| Volume: | 0.16 cubic inches | @ 25° C 1010 ohms min. @ 100VDC |
| Markings: | Trade name, Cat. No., Date Code, and Schematic | |
| Dielectric Strength: | ||
| 350 VAC, rms, 60Hz across open contacts or 500 VDC max. | ||
| ENVIRONMENTAL | Contacts: | |
| Temperature: | -55° C to +75° C | Capacitance: .3 pF max. |
| Vibration: | 0.6" double amplitude 10 to 55 Hz or 10G to 500 Hz. | Resistance 0.10 ohm max. (measured at 6VDC, 0.1 to 1.0 amp) |
| Shock: | 20G for 11 ms. | Rating: |
| Power 30 volt amperes, max. Voltage 300 volts DC or AC peak, max. Current 1 amp switched, max./3 amps, carry only, max. |
||
| Life: | ||
| Full Load 100,000 operations/min. Signal Levels 10 x 106 operations/min. |
||
Home Page
10 Series
11 Series
15 Series
16 Series
17 Series
18 Series
30 Series
111 Series
801 Series
"Contact Us!"![]() Last Updated:January 28, 1998 Copyright 1997-1998 Electrodyne, Inc. All Rights Reserved Website Produced by iSITE Communications |