Logo  Company Name

    11200 SE 21st Street, Milwaukie, OR 97222   TEL (503) 654-0711/FAX (503) 654-1959
10 Series Relay 11 Series Relay 15 Series Relay 18 Series Relay 30 Series Relay       16 Series Relay 17 Series Relay 111 Series Relay 801 Series Relay home
10 Series: 11 Series: 15 Series: 18 Series: 30 Series:       16 Series: 17 Series: 111 Series: 801 Series:

LOOP SENSOR RELAY
1001 SERIES Sensitive Current Sensor

The Electrodyne type 1001 series relay is used to sense small signal currents used in communication networks and indicate change in state conditions. The relays incorporate two balanced windings, 25 ohms each, which are inserted in each side of the line maintaining longitudinal balance. The must operate current is 19 ma. Isolation between coil and contact is 1000 VRMS. With terminals spaced on a .100 inch grid spacing, it is designed to be mounted into standard sockets or circuit boards on the same lead spacing. We invite your inquiries on the standard relays or any other variations to fit your specific needs.

  FEATURES

  • Miniature "DIP" package, sealed
  • Dual coil maintains line balance
  • Wide choice of contact formsn
  • High voltage isolation

  APPLICATIONS

  • Off hook sensor
  • Busy lamp indicator
  • Long line sensor
  • Message receival systems

 
SPECIFICATIONS
MECHANICAL ELECTRICAL
Weight: 4.5 grams max. Duty Cycle: Continuous
Enclosure: Plastic 94 V0/94-5V Insulation Resistance:
Volume: 0.16 cubic inches    @ 25° C    1010 ohms min. @ 100VDC
Markings: Trade name, Cat. No., Date Code, and Schematic    
Dielectric Strength:
   350 VAC, rms, 60Hz across open contacts or 500 VDC max.
ENVIRONMENTAL Contacts:
Temperature: -55° C to +75° C    Capacitance:    .3 pF max.
Vibration: 0.6" double amplitude 10 to 55 Hz or 10G to 500 Hz.    Resistance       0.10 ohm max.
(measured at 6VDC, 0.1 to 1.0 amp)
Shock: 20G for 11 ms. Rating:
Power     30 volt amperes, max.
Voltage   300 volts DC or AC peak, max.
Current   1 amp switched, max./3 amps, carry only, max.
Life:
Full Load    100,000 operations/min.
Signal Levels    10 x 106 operations/min.